NSN: 5925-00-173-4422

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Thread Quantity Per Inch

    28

  • External Actuator Linkage Arrangement

    one and two linked

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.070 minimum at 200 pct all locations and 1.800 maximum at 200 pct all locations

  • Terminal Type And Quantity

    4 threaded stud

  • Inclosure Protection Type For Which Designed

    corrosion resistant and fungus resistant

  • Mounting Surface To Terminal End Distance

    2.455 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    60.0 dc all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.830 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.138 inches

  • Body Width

    1.560 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.760 inches nominal

  • Boss Height

    0.135 inches maximum

  • Body Length

    2.300 inches maximum

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Center To Center Distance Between Terminals Parallel To Length

    1.690 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.760 inches maximum

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc all locations

  • Actuator Function

    reset

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...