NSN: 5925-00-173-7634
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Terminals Parallel To Length
1.062 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 nominal at 200 pct single location
-
Overall Length
3.156 inches nominal
-
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location
-
Case Material
plastic
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Release Ambient Temp Rating
77.0 deg fahrenheit nominal single location
-
Body Style
single pole type
-
Maximum Continuous Load Current Rating Per Pole
135.0 amperes dc single location
-
Reset Method
automatic
-
Body Width
1.875 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
900.0 dc single location
-
Nominal Thread Size
0.190 inches
-
Thread Series Designator
unf
-
Terminal Type And Quantity
2 screw
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.406 inches nominal
-
Pole Quantity
1
-
Internal Trip Release Configuration
series trip single location
-
Trip Release Characteristic
time delay single location