NSN: 5925-00-174-0262

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.375 inches

  • Mounting Surface To Terminal End Distance

    1.656 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Circuit Protection Type

    overcurrent single location

  • Bushing Length

    0.380 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches nominal

  • Body Width

    0.625 inches nominal

  • Trip Release Characteristic

    instantaneous single location

  • Case Material

    metal

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Thread Series Designator

    unef

  • Trip Release Method

    magnetic single location

  • Terminal Type And Quantity

    2 wire hook

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Frequency In Hertz

    60.0 single location

  • Ultimate Trip Time Per Pole In Seconds

    0.005 nominal single location

  • Switch Terminal Type

    wire hook

  • Body Style

    single pole type

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Auxiliary Switch Function And Quantity

    1 control

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Pole Quantity

    1

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Actuator Position Designation

    at pole one

  • Switch Location And Position Designation

    internal at pole one

  • Body Length

    1.622 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...