NSN: 5925-00-174-3301

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    10b multipole-single actuator type

  • Body Width

    10.500 inches nominal

  • Case Material

    metal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    15.875 inches nominal

  • Mounting Surface To Terminal End Distance

    11.875 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    90.000 nominal at 400 pct all locations

  • Terminal Type And Quantity

    4 threaded stud

  • ~1

    ting voltage type and rating per pole in volts

  • Reference Number Differentiating Characteristics

    as differentiated by pole quantity,maximum continuous load currentper pole,opera

  • Body Length

    17.000 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    14.375 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    7.000 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.438 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    3.500 inches nominal

  • Boss Height

    0.250 inches nominal

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Maximum Continuous Load Current Rating Per Pole

    320.0 amperes dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    355.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 dc all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    175.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    series trip all locations

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...