NSN: 5925-00-184-5972

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    relay trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct and 9.000 maximum at 200 pct first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct and 9.000 maximum at 200 pct second location

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Frequency In Hertz

    400.0

  • Precious Material

    silver

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    9 wire hook

  • Body Style

    1b multipole-single actuator type

  • Body Width

    1.987 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac first location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac second location

  • Operating Voltage Type And Rating Per Pole In Volts

    4.0 dc third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac first location

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    time delay first location

  • Trip Release Characteristic

    time delay second location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Nominal Thread Size

    0.375 inches

  • Unpackaged Unit Weight

    5.000 ounces

  • Precious Material And Location

    contact surfaces silver

  • Bushing Length

    0.280 inches minimum and 0.380 inches maximum

  • Body Length

    1.562 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    400.0 milliamperes dc third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    750.0 dc third location

  • Trip Release Characteristic

    instantaneous third location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Manual Actuator Type And Quantity

    1 toggle

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...