Technical Characteristics

  • Terminal Type And Quantity

    6 bus bar

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Body Height

    17.000 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac all locations

  • Switch Current Rating And Type In Amps

    12.0 ac and 9.0 dc

  • Mounting Facility Type And Quantity

    4 slot and 4 unthreaded hole

  • Body Length

    17.562 inches nominal

  • Body Width

    12.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    3.625 inches nominal

  • Switch Voltage Rating And Type In Volts

    208.0 ac and 120.0 dc

  • Special Features

    long delay pickup,long time delayband,instantaneous pickup settings adjustable.

  • Boss Height

    0.375 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    shunt trip all locations

  • Frequency In Hertz

    60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.375 inches nominal

  • Mounting Slot Width

    0.187 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    600.0 amperes ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    11.625 inches nominal

  • Manual Actuator Type And Quantity

    1 rotary

  • Case Material

    metal

  • Ultimate Trip Time Per Pole In Seconds

    56.000 nominal all locations

  • Body Style

    multipole-single actuator type

  • Unthreaded Mounting Hole Diameter

    0.500 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Trip Release Method

    magnetic all locations

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +280.0/+460.0 ac all locations and +1750.0/+5250.0 ac all locations

  • Actuator Position Designation

    at pole one

  • Features Provided

    adjustable trip release

  • Switch Terminal Type

    threaded stud

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Reset Actuator Voltage Rating And Type In Volts

    208.0 ac

  • Reset Method

    electric

  • Auxiliary Switch Function And Quantity

    12 alarm

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    10.562 inches nominal

  • Actuator Function

    reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    75.000 minimum at 100 pct all locations and 1000.000 maximum at 100 pct all locations and 56.000 minimum at 150 pct all locations and 46.000 minimum at 200 pct all locations and 34.000 minimum at 400 pct all locations and 28.000 minimum at 500 pct all

  • ~1

    locations and 90.000 maximum at 400 pct all loca

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...