NSN: 5925-00-201-6953

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.500 minimum at 200 pct and

  • Inclosure Protection Type For Which Designed

    dustproof and

  • Terminal Type And Quantity

    2 compression

  • Body Style

    9a single pole type

  • Body Length

    5.260 inches maximum

  • Body Width

    1.510 inches maximum

  • Body Height

    2.698 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    4.369 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Boss Height

    0.208 inches minimum and

  • Boss Height

    0.228 inches maximum

  • Mounting Facility Type And Quantity

    4 unthreaded hole and

  • Iii Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Trip Release Characteristic

    time delay single location

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.164 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    fungus proof

  • Frequency In Hertz

    60.0 single location

  • Thread Series Designator

    unc

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Iii Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    1

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.994 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.974 inches minimum and

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.369 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.349 inches minimum and

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    4.349 inches minimum and

  • Case Material

    plastic

  • Body Height

    2.678 inches minimum and

  • Body Width

    1.490 inches minimum and

  • Body Length

    5.240 inches minimum and

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...