NSN: 5925-00-204-6609
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Actuator Function
reset
-
Trip Release Method
magnetic single location
-
Thread Series Designator
unc
-
Reset Method
manual
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Pole Quantity
1
-
Manual Actuator Type And Quantity
1 toggle
-
Nominal Thread Size
0.138 inches
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Overall Height
3.172 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location
-
Frequency In Hertz
60.0 single location
-
Case Material
plastic
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac single location
-
Terminal Type And Quantity
2 threaded stud
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.063 inches nominal
-
Overall Length
2.500 inches nominal
-
Mounting Facility Type And Quantity
2 threaded hole
-
Overall Width
0.750 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location
-
Thread Quantity Per Inch
32
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.900 minimum at 200 pct single location and 0.280 maximum at 300 pct single location
-
Circuit Protection Type
overcurrent single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
2000.0 single location