Technical Characteristics

  • Body Length

    8.000 inches nominal

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    175.0 amperes ac and 175.0 amperes dc .

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac and 250.0 dc .

  • Circuit Protection Type

    overcurrent .

  • Trip Release Method

    thermal-magnetic .

  • Trip Release Characteristic

    instantaneous and time delay .

  • Trip Delay Time In Seconds Per Rated Continuous Current

    150.000 minimum at 200 pct and 250.000 maximum at 200 pct .

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Body Style

    caaql 11b

  • Body Width

    4.500 inches nominal

  • Body Height

    3.500 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    6.562 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.203 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    7.125 inches nominal

  • Boss Height

    0.125 inches nominal

  • Pole Quantity

    3

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 ac and 10000.0 dc .

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Frequency In Hertz

    60.0

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal .

  • Terminal Type And Quantity

    6 compression

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...