NSN: 5925-00-227-0394

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    reset

  • Fragility Factor

    moderately rugged

  • Body Width

    1.875 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Manual Actuator Type And Quantity

    1 push button

  • Case Material

    plastic

  • Overall Length

    3.156 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.062 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Frequency In Hertz

    60.0 single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Body Style

    single pole type

  • Mounting Surface To Terminal End Distance

    1.109 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Trip Release Ambient Temp Rating

    77.0 deg fahrenheit nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct single location and 150.000 maximum at 200 pct single location

  • Internal Trip Release Configuration

    series trip single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    875.0 ac single location and 875.0 dc single location

  • Pole Quantity

    1

  • Unpackaged Unit Weight

    5.000 ounces

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.406 inches nominal

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Inclosure Protection Type For Which Designed

    shockproof

  • Maximum Continuous Load Current Rating Per Pole

    120.0 amperes ac single location and 120.0 amperes dc single location

  • Terminal Type And Quantity

    2 screw

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...