NSN: 5925-00-229-3519
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
locations and 46.000 minimum at 200 pct all loca
-
Actuator Function
reset
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
35000.0 ac all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
10.562 inches nominal
-
Auxiliary Switch Function And Quantity
12 alarm
-
Reset Method
electric
-
Reset Actuator Voltage Rating And Type In Volts
208.0 ac
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Overall Length
17.000 inches nominal
-
Body Style
rectangular dimensional envelope
-
Switch Terminal Type
threaded stud
-
Features Provided
adjustable trip release
-
Actuator Position Designation
at pole one
-
Adjustable Trip Setting Current Range Per Pole In Amps
+280.0/+460.0 ac all locations and +1750.0/+5250.0 ac all locations
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Trip Delay Time In Seconds Per Rated Continuous Current
75.000 minimum at 100 pct all locations and 300.000 maximum at 200 pct all locations and 90.000 maximum at 400 pct all locations and 10.000 minimum at 1000 pct all locations and 65.000 maximum at 500 pct all locations and 34.000 minimum at 400 pct all
-
Trip Release Characteristic
instantaneous all locations and time delay all locations
-
Trip Release Method
magnetic all locations
-
Switch Contact Arrangement
single pole, double throw
-
Unthreaded Mounting Hole Diameter
0.500 inches nominal
-
Ultimate Trip Time Per Pole In Seconds
56.000 nominal all locations
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 rotary
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
11.625 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
600.0 amperes ac all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Mounting Slot Width
0.187 inches nominal
-
Frequency In Hertz
60.0 all locations
-
Internal Trip Release Configuration
shunt trip all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Overall Width
12.750 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
3.625 inches nominal
-
Special Features
long delay pickup,long time delayband,instantaneous pickup settings adjustable.
-
Body Width
12.750 inches nominal
-
Body Length
17.562 inches nominal
-
Switch Voltage Rating And Type In Volts
208.0 ac and 46.0 dc
-
Switch Current Rating And Type In Amps
12.0 ac and 24.0 dc
-
Overall Height
16.188 inches nominal
-
Body Height
17.000 inches nominal
-
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
-
Terminal Type And Quantity
6 bus bar