NSN: 5925-00-229-3519

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    locations and 46.000 minimum at 200 pct all loca

  • Actuator Function

    reset

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    35000.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    10.562 inches nominal

  • Auxiliary Switch Function And Quantity

    12 alarm

  • Reset Method

    electric

  • Reset Actuator Voltage Rating And Type In Volts

    208.0 ac

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Overall Length

    17.000 inches nominal

  • Body Style

    rectangular dimensional envelope

  • Switch Terminal Type

    threaded stud

  • Features Provided

    adjustable trip release

  • Actuator Position Designation

    at pole one

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +280.0/+460.0 ac all locations and +1750.0/+5250.0 ac all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Trip Delay Time In Seconds Per Rated Continuous Current

    75.000 minimum at 100 pct all locations and 300.000 maximum at 200 pct all locations and 90.000 maximum at 400 pct all locations and 10.000 minimum at 1000 pct all locations and 65.000 maximum at 500 pct all locations and 34.000 minimum at 400 pct all

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Trip Release Method

    magnetic all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Unthreaded Mounting Hole Diameter

    0.500 inches nominal

  • Ultimate Trip Time Per Pole In Seconds

    56.000 nominal all locations

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 rotary

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    11.625 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    600.0 amperes ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Mounting Slot Width

    0.187 inches nominal

  • Frequency In Hertz

    60.0 all locations

  • Internal Trip Release Configuration

    shunt trip all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Overall Width

    12.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    3.625 inches nominal

  • Special Features

    long delay pickup,long time delayband,instantaneous pickup settings adjustable.

  • Body Width

    12.750 inches nominal

  • Body Length

    17.562 inches nominal

  • Switch Voltage Rating And Type In Volts

    208.0 ac and 46.0 dc

  • Switch Current Rating And Type In Amps

    12.0 ac and 24.0 dc

  • Overall Height

    16.188 inches nominal

  • Body Height

    17.000 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Terminal Type And Quantity

    6 bus bar

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...