NSN: 5925-00-231-3588

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Height

    3.812 inches nominal

  • Switch Terminal Type

    tab, solder lug

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    4.125 inches nominal

  • Switch Voltage Rating And Type In Volts

    480.0 ac and 250.0 dc

  • Reset Method

    manual

  • Body Length

    6.310 inches nominal

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.380 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Special Features

    undervoltage trip right pole

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.880 inches nominal

  • Switch Current Rating And Type In Amps

    6.0 ac and 0.250 dc

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Unthreaded Mounting Hole Diameter

    0.203 inches nominal

  • Boss Height

    0.125 inches nominal

  • Terminal Type And Quantity

    6 compression and 2 wire lead

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.025 minimum at 150 pct all locations and 9.000 maximum at 150 pct all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    18000.0 ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    5.250 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...