NSN: 5925-00-233-1962

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    reset

  • Fragility Factor

    moderately rugged

  • Bushing Length

    0.250 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Maximum Continuous Load Current Rating Per Pole

    8.0 amperes ac single location and 8.0 amperes dc single location

  • Pole Quantity

    1

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    80.0 ac all locations and 80.0 dc all locations

  • Thread Quantity Per Inch

    28.0

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 40.000 maximum at 200 pct single location

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches nominal

  • Thread Series Designator

    unef

  • Body Width

    0.570 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 28.0 dc single location

  • Mounting Surface To Terminal End Distance

    1.810 inches nominal

  • Body Length

    1.140 inches nominal

  • Unpackaged Unit Weight

    2.000 ounces

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Internal Trip Release Configuration

    series trip all locations

  • Manual Actuator Type And Quantity

    1 push button

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Inclosure Protection Type For Which Designed

    shockproof

  • Nominal Thread Size

    0.438 inches

  • Arc Quenching Method

    air

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...