NSN: 5925-00-235-1936
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Bushing Length
0.360 inches minimum and 0.380 inches maximum
-
Body Length
1.464 inches minimum and 1.526 inches maximum
-
Body Width
1.841 inches minimum and 1.903 inches maximum
-
Case Material
metal
-
Center To Center Distance Between Terminals Parallel To Length
0.870 inches minimum and 0.906 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.620 inches minimum and 0.630 inches maximum
-
Fragility Factor
moderately rugged
-
Arc Quenching Method
magnetic blowout
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac
-
Circuit Protection Type
overcurrent
-
Trip Release Method
magnetic-hydraulic
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Position Designation
at pole two
-
Internal Trip Release Configuration
series trip
-
Nominal Thread Size
0.375 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.180 minimum at 200 pct and 0.690 maximum at 200 pct
-
Thread Series Designator
unef
-
Terminal Type And Quantity
6 wire hook
-
Body Style
multipole-single actuator type
-
Mounting Surface To Terminal End Distance
1.647 inches minimum and 1.709 inches maximum
-
Pole Quantity
3
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac
-
Trip Release Characteristic
time delay
-
Ultimate Trip Time Per Pole In Seconds
0.800 minimum and 5.000 maximum
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Inclosure Protection Type For Which Designed
explosion resistant and fungus resistant and hermetically sealed
-
Frequency In Hertz
400.0
-
Test Data Document
18876-11151920 drawing