NSN: 5925-00-235-1936

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.360 inches minimum and 0.380 inches maximum

  • Body Length

    1.464 inches minimum and 1.526 inches maximum

  • Body Width

    1.841 inches minimum and 1.903 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.870 inches minimum and 0.906 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.620 inches minimum and 0.630 inches maximum

  • Fragility Factor

    moderately rugged

  • Arc Quenching Method

    magnetic blowout

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic-hydraulic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at pole two

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.180 minimum at 200 pct and 0.690 maximum at 200 pct

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    6 wire hook

  • Body Style

    multipole-single actuator type

  • Mounting Surface To Terminal End Distance

    1.647 inches minimum and 1.709 inches maximum

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Time Per Pole In Seconds

    0.800 minimum and 5.000 maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Inclosure Protection Type For Which Designed

    explosion resistant and fungus resistant and hermetically sealed

  • Frequency In Hertz

    400.0

  • Test Data Document

    18876-11151920 drawing

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...