NSN: 5925-00-235-8521

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Body Style

    multipole-single actuator type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    600.000 maximum at 200 pct all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    9.250 inches nominal

  • Terminal Type And Quantity

    6 compression

  • Center To Center Distance Between Terminals Parallel To Width

    2.000 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Unthreaded Mounting Hole Diameter

    0.203 inches nominal

  • Body Length

    11.000 inches nominal

  • Boss Height

    0.219 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    300.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Case Material

    plastic

  • Actuator Function

    trip-reset

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Actuator Position Designation

    at pole two

  • Body Height

    4.062 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    9.250 inches nominal

  • Body Width

    6.000 inches nominal

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.000 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...