NSN: 5925-00-245-3391

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 dc first location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 dc first location

  • Manual Actuator Type And Quantity

    2 toggle

  • Internal Trip Release Configuration

    shunt trip second location

  • Maximum Continuous Load Current Rating Per Pole

    200.0 milliamperes dc first location

  • Body Width

    1.530 inches nominal

  • External Actuator Linkage Arrangement

    one and two linked

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct second location and 10.000 maximum at 200 pct second location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Internal Trip Release Configuration

    relay trip first location

  • Maximum Continuous Load Current Rating Per Pole

    18.0 amperes ac second location

  • Case Material

    plastic

  • Mounting Surface To Terminal End Distance

    2.630 inches nominal

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Nominal Thread Size

    0.190 inches

  • Reset Method

    manual

  • Boss Height

    0.150 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 ac second location

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Body Length

    2.530 inches nominal

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Arc Quenching Method

    air

  • Body Style

    multipole-multiple actuator type

  • Frequency In Hertz

    60.0 second location

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Trip Release Characteristic

    instantaneous first location

  • Trip Release Characteristic

    time delay second location

  • Terminal Type And Quantity

    7 threaded stud

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...