NSN: 5925-00-245-3391
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3000.0 dc first location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 dc first location
-
Manual Actuator Type And Quantity
2 toggle
-
Internal Trip Release Configuration
shunt trip second location
-
Maximum Continuous Load Current Rating Per Pole
200.0 milliamperes dc first location
-
Body Width
1.530 inches nominal
-
External Actuator Linkage Arrangement
one and two linked
-
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct second location and 10.000 maximum at 200 pct second location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
-
Internal Trip Release Configuration
relay trip first location
-
Maximum Continuous Load Current Rating Per Pole
18.0 amperes ac second location
-
Case Material
plastic
-
Mounting Surface To Terminal End Distance
2.630 inches nominal
-
Fragility Factor
moderately rugged
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Nominal Thread Size
0.190 inches
-
Reset Method
manual
-
Boss Height
0.150 inches nominal
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3000.0 ac second location
-
Mounting Facility Type And Quantity
4 threaded hole
-
Body Length
2.530 inches nominal
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic-hydraulic all locations
-
Arc Quenching Method
air
-
Body Style
multipole-multiple actuator type
-
Frequency In Hertz
60.0 second location
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Trip Release Characteristic
instantaneous first location
-
Trip Release Characteristic
time delay second location
-
Terminal Type And Quantity
7 threaded stud
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations