NSN: 5925-00-257-9536

Technical Characteristics

  • Arc Quenching Method

    magnetic blowout

  • Unthreaded Mounting Hole Diameter

    0.188 inches nominal

  • Body Length

    6.000 inches nominal

  • Bushing Length

    0.125 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations and 5000.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Length

    5.062 inches nominal

  • Inclosure Protection Type For Which Designed

    dustproof and general purpose and fungus resistant

  • Unpackaged Unit Weight

    3.000 pounds

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.500 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Body Style

    multipole-multiple actuator type

  • Body Width

    2.750 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Terminal Type And Quantity

    4 compression

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes ac all locations and 70.0 amperes dc all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Mounting Surface To Terminal End Distance

    3.375 inches nominal

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    85.000 minimum at 200 pct all locations and 240.000 maximum at 200 pct all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 250.0 dc all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...