NSN: 5925-00-258-9577
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Case Material
plastic
-
Pole Quantity
1
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac
-
Trip Release Method
magnetic
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip w/auxiliary load terminal
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct and 9.000 maximum at 200 pct
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Frequency In Hertz
63.0
-
Thread Series Designator
unc
-
Terminal Type And Quantity
3 threaded stud
-
Body Length
2.500 inches nominal
-
Body Width
0.750 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
-
Boss Height
0.125 inches nominal
-
Mounting Surface To Terminal End Distance
2.547 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac
-
Circuit Protection Type
overcurrent
-
Trip Release Characteristic
time delay
-
Ultimate Trip Time Per Pole In Seconds
8.000 minimum and 30.000 maximum
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Position Designation
at pole one