NSN: 5925-00-258-9804
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency In Hertz
60.0 single location
-
Terminal Type And Quantity
2 threaded stud
-
Overall Height
2.484 inches nominal
-
Overall Width
0.750 inches nominal
-
Pole Quantity
1
-
Mounting Facility Type And Quantity
thd bushing
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location
-
Manual Actuator Type And Quantity
2 toggle
-
Actuator Function
trip-reset
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 nominal at 125 pct single location and 3.000 nominal at 200 pct and 1.200 nominal at 300 pct
-
Thread Series Designator
unc
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Overall Length
2.500 inches nominal
-
Case Material
plastic
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
magnetic single location
-
Trip Release Characteristic
instantaneous single location and time delay
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location