NSN: 5925-00-265-3147

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Pitch Diameters

    0.3503 to 0.3537 inches

  • Bushing Length

    0.380 inches maximum

  • Body Width

    1.875 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac second location

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Internal Trip Release Configuration

    relay trip third location

  • Internal Trip Release Configuration

    series trip first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.500 maximum at 200 pct all locations

  • Switch Current Rating And Type In Amps

    0.5 dc

  • ~1

    ent

  • Special Features

    pole three dc time delay 0.090 sec to 0.600 sec at 200 pct rated continuous curr

  • Frequency In Hertz

    400.0 all locations

  • Body Style

    1b multipole-single actuator type

  • Body Length

    1.500 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac first location

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac second location

  • Maximum Continuous Load Current Rating Per Pole

    250.0 milliamperes dc third location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac and

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc third location

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Auxiliary Switch Function And Quantity

    2 alarm

  • Internal Trip Release Configuration

    series trip second location

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct and

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Switch Terminal Type

    tab, solder lug

  • Switch Current Rating And Type In Amps

    0.5 ac and

  • Switch Voltage Rating And Type In Volts

    120.0 ac and

  • Switch Voltage Rating And Type In Volts

    50.0 dc

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    8 wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...