Technical Characteristics

  • Unpackaged Unit Weight

    1.000 ounces

  • Nominal Thread Size

    0.375 inches

  • Bushing Length

    0.400 inches nominal

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Fragility Factor

    moderately rugged

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 single location

  • Body Width

    0.570 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    100.0 ac single location and 100.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location and 10.0 amperes dc single location

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    0.704 inches nominal

  • Frequency In Hertz

    400.0 single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 40.000 maximum at 200 pct single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Pole Quantity

    1

  • Thread Quantity Per Inch

    27

  • Manual Actuator Type And Quantity

    1 push-pull

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Body Length

    1.140 inches nominal

  • Mounting Surface To Terminal End Distance

    1.810 inches nominal

  • Terminal Type And Quantity

    2 tab w/screw

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 28.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...