Technical Characteristics

  • Thread Series Designator

    unc

  • Test Data Document

    81349-mil-c-55629 specification

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct and 0.800 maximum at 200 pct

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Trip Release Method

    magnetic

  • Circuit Protection Type

    overcurrent

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc

  • Thread Quantity Per Inch

    32

  • Special Handling Feature

    magnetic

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Pole Quantity

    2

  • Boss Height

    0.109 inches minimum and 0.171 inches maximum

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and 2.078 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Case Material

    plastic

  • Thread Pitch Diameters

    p0.1177/p0.1214 inches

  • Maximum Continuous Load Current Rating Per Pole

    7.0 amperes dc

  • Arc Quenching Method

    magnetic blowout

  • Mounting Surface To Terminal End Distance

    2.553 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.719 inches minimum and 0.781 inches maximum

  • Body Width

    1.469 inches minimum and 1.531 inches maximum

  • Body Length

    2.510 inches maximum

  • Specification/Standard Data

    81349-mil-c-55629/3 government specification

  • Terminal Type And Quantity

    4 threaded stud

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • External Actuator Linkage Arrangement

    one and two linked

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    2 toggle

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...