NSN: 5925-00-280-1237

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unef

  • Switch Current Rating And Type In Amps

    1.0 ac and 0.5 dc

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Switch Location And Position Designation

    internal at pole one

  • Auxiliary Switch Function And Quantity

    1 control

  • Actuator Position Designation

    between pole one and two

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay

  • Trip Release Method

    magnetic-hydraulic

  • Circuit Protection Type

    overcurrent

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Special Handling Feature

    magnetic

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Switch Contact Arrangement

    single pole,double throw

  • Case Material

    metal

  • Body Width

    1.250 inches maximum

  • Bushing Length

    0.375 inches maximum

  • Terminal Type And Quantity

    4 wire hook

  • Frequency In Hertz

    400.0

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Switch Terminal Type

    tab,solder lug

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 150 pct and 15.000 maximum at 150 pct and 0.020 minimum at 400 pct and 0.100 maximum at 400 pct

  • Nominal Thread Size

    0.375 inches

  • Internal Trip Release Configuration

    series trip

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Time Per Pole In Seconds

    6.000 minimum and 30.000 maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    2

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Body Length

    1.500 inches maximum

  • Body Style

    multipole-single actuator type

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.