NSN: 5925-00-283-6519

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations and 5000.0 dc all locations

  • Pole Quantity

    2

  • Actuator Function

    trip w/separate reset

  • Reset Method

    manual

  • Unthreaded Mounting Hole Diameter

    0.196 inches nominal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Arc Quenching Method

    magnetic blowout

  • Body Length

    6.000 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations and 15.0 amperes dc all locations

  • Center To Center Distance Between Terminals Parallel To Length

    5.250 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    5.218 inches nominal

  • Case Material

    plastic

  • Body Height

    3.187 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations and 250.0 dc all locations

  • Terminal Type And Quantity

    4 screw

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Trip Release Method

    magnetic all locations

  • Body Width

    2.750 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Boss Height

    0.188 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    75.000 nominal at 200 pct all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...