NSN: 5925-00-283-6840
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Height
2.688 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
4.359 inches nominal
-
Center To Center Distance Between Terminals Parallel To Width
1.000 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.359 inches nominal
-
Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Storage Type
general purpose warehouse
-
Body Style
9b multipole-single actuator type
-
Body Length
5.250 inches nominal
-
Body Width
3.000 inches nominal
-
Case Material
plastic
-
Unthreaded Mounting Hole Diameter
0.190 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.000 inches nominal
-
Fragility Factor
moderately rugged
-
Boss Height
0.219 inches nominal
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent second location
-
Circuit Protection Type
overcurrent third location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Position Designation
at pole two
-
Internal Trip Release Configuration
series trip third location
-
Trip Delay Time In Seconds Per Rated Continuous Current
210.000 nominal at 200 pct second location
-
~1
ant
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant and shock resistant and vibration resist
-
Frequency In Hertz
60.0
-
Unpackaged Unit Weight
29.000 ounces
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac and 25.0 amperes dc all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac and 125.0 dc all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac and 5000.0 dc all locations
-
Circuit Protection Type
overvoltage first location
-
Trip Release Method
magnetic-hydraulic all locations
-
Trip Release Characteristic
instantaneous first location
-
Trip Release Characteristic
time delay second location
-
Trip Release Characteristic
time delay third location
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip second location
-
Internal Trip Release Configuration
shunt trip first location
-
Trip Delay Time In Seconds Per Rated Continuous Current
210.000 nominal at 200 pct third location
-
Terminal Type And Quantity
5 threaded stud