Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    multipole-single actuator type

  • Body Length

    5.240 inches minimum and 5.260 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.974 inches minimum and 0.994 inches maximum

  • Boss Height

    0.208 inches minimum and 0.228 inches maximum

  • Pole Quantity

    2

  • Arc Quenching Method

    magnetic blowout

  • Body Width

    1.990 inches minimum and 2.010 inches maximum

  • Body Height

    2.677 inches minimum and 2.697 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    4.349 inches minimum and 4.369 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.052 inches minimum and 3.072 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.990 inches minimum and 1.010 inches maximum

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.500 minimum at 200 pct and 20.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Frequency In Hertz

    60.0

  • Terminal Type And Quantity

    4 threaded stud

  • Mounting Facility Type And Quantity

    4 threaded hole and 2 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.164 inches

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...