NSN: 5925-00-313-6049

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Terminal Type

    tab, solder lug

  • Trip Release Characteristic

    instantaneous all locations

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    100.0 milliamperes dc second location

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Facility Type And Quantity

    thd bushing w/panel seal

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc all locations and 500.0 dc all locations

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Terminal Type And Quantity

    4 wire hook

  • Switch Contact Arrangement

    single pole, double throw

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Trip Release Method

    magnetic-hydraulic all locations and magnetic-hydraulic all locations

  • Body Style

    multipole-single actuator type

  • Maximum Continuous Load Current Rating Per Pole

    750.0 milliamperes dc first location

  • Case Material

    metal

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc first location

  • Ultimate Trip Time Per Pole In Seconds

    0.010 minimum all locations and 0.040 maximum all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Length

    1.500 inches maximum

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc second location

  • Body Width

    1.250 inches maximum

  • Thread Series Designator

    unef

  • External Actuator Linkage Arrangement

    one and two linked

  • Bushing Length

    0.380 inches maximum

  • Switch Location And Position Designation

    internal at pole one

  • Auxiliary Switch Function And Quantity

    1 control

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...