NSN: 5925-00-335-6321

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac first location

  • Mounting Surface To Terminal End Distance

    2.640 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Trip Release Characteristic

    instantaneous all locations

  • Auxiliary Switch Function And Quantity

    2 alarm

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes dc third location

  • Boss Height

    0.150 inches nominal

  • Actuator Function

    trip-reset

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac first location and 5000.0 dc first location

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac second location

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Switch Contact Arrangement

    single pole, double throw

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac third location and 5000.0 dc third location

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Body Width

    2.500 inches nominal

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 toggle

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc third location

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac first location

  • Switch Location And Position Designation

    internal at pole one

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Terminal Type And Quantity

    6 threaded stud

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac second location and 5000.0 dc second location

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Case Material

    metal

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Body Length

    2.500 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...