NSN: 5925-00-346-7970

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Height

    1.319 inches minimum and 1.381 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.469 inches minimum and 0000 points maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.531 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.593 inches minimum and 0.655 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac

  • Circuit Protection Type

    overcurrent

  • Body Length

    1.840 inches maximum

  • Body Width

    0.730 inches minimum and 0.770 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.500 minimum at 200 pct and 20.000 maximum at 200 pct

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal

  • Unpackaged Unit Weight

    59.0 grams

  • Thread Series Designator

    uns

  • Body Style

    multipole-single actuator type

  • Bushing Length

    0.219 inches minimum and 0.281 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Trip Release Method

    thermal

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Nominal Thread Size

    0.438 inches

  • Inclosure Protection Type For Which Designed

    shock resistant

  • Frequency In Hertz

    400.0

  • Terminal Type And Quantity

    6 tab w/screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...