NSN: 5925-00-350-4589
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Inclosure Protection Type For Which Designed
moisture resistant
-
Body Width
1.875 inches nominal
-
Nominal Thread Size
0.190 inches
-
Thread Series Designator
unf
-
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location
-
Maximum Continuous Load Current Rating Per Pole
105.0 amperes dc single location
-
Terminal Type And Quantity
2 screw
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
~1
data on certain environmental and performanc
-
Case Material
plastic
-
Overall Length
3.156 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
1.062 inches nominal
-
Reset Method
automatic
-
Trip Delay Time In Seconds Per Rated Continuous Current
30.000 nominal at 200 pct single location
-
Mounting Surface To Terminal End Distance
1.406 inches nominal
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Test Data Document
81348-mil-c-13516 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Trip Release Characteristic
time delay single location
-
Internal Trip Release Configuration
series trip single location
-
Pole Quantity
1
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.406 inches nominal
-
Arc Quenching Method
air
-
Trip Release Method
thermal single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location