NSN: 5925-00-400-3036

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Time Per Pole In Seconds

    0.200 minimum and 7.000 maximum all locations

  • Trip Release Method

    magnetic all locations

  • Circuit Protection Type

    overcurrent all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc all locations

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Nonturn Device Radius

    0.336 inches nominal

  • Nonturn Device Location

    at 6 oclock

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Case Material

    metal

  • Body Style

    1b multipole-single actuator type

  • Switch Current Rating And Type In Amps

    0.5 dc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct and 0.950 maximum at 200 pct all locations

  • Switch Location And Position Designation

    internal at each pole

  • Nominal Thread Size

    0.375 inches

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Position Designation

    at each pole

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Characteristic

    time delay all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc all locations

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes dc all locations

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    2

  • Switch Contact Arrangement

    single pole, double throw

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Body Width

    1.281 inches maximum

  • Body Length

    1.562 inches maximum

  • Bushing Length

    0.280 inches minimum and 0.380 inches maximum

  • Reset Method

    manual

  • Actuator Function

    reset

  • Auxiliary Switch Function And Quantity

    1 control

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Switch Terminal Type

    wire hook

  • Switch Voltage Rating And Type In Volts

    50.0 dc

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    4 wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...