NSN: 5925-00-410-7560

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    1.735 inches minimum and 1.765 inches maximum

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Reset Method

    manual

  • Switch Terminal Type

    turret

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Pole Quantity

    1

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct single location and 2.000 maximum at 200 pct single location

  • Body Width

    0.615 inches minimum and 0.635 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    1.225 inches minimum and 1.255 inches maximum

  • Auxiliary Switch Function And Quantity

    1 control

  • Thread Series Designator

    uns

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 dc single location

  • Terminal Type And Quantity

    2 tab, solder lug

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Switch Current Rating And Type In Amps

    7.0 dc

  • Body Style

    single pole type

  • Switch Contact Arrangement

    single pole, single throw, normally open

  • Mounting Surface To Terminal End Distance

    1.623 inches minimum and 1.653 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc single location

  • Bushing Length

    0.280 inches minimum and 0.300 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc single location

  • Nominal Thread Size

    0.469 inches

  • Switch Location And Position Designation

    internal at pole one

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...