Technical Characteristics

  • Bushing Length

    0.380 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.190 minimum at 200 pct all locations and 0.700 maximum at 200 pct all locations

  • Terminal Type And Quantity

    6 wire hook

  • Body Length

    1.937 inches maximum

  • Thread Series Designator

    unef

  • Frequency In Hertz

    400.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Body Width

    1.562 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    between pole one and two

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations

  • Body Style

    multipole-single actuator type

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Release Method

    magnetic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.250 inches nominal

  • Mounting Surface To Terminal End Distance

    1.826 inches maximum

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Fragility Factor

    moderately rugged

  • Case Material

    plastic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...