NSN: 5925-00-426-9111

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    4c multipole-multiple actuator type

  • Body Length

    4.740 inches minimum and

  • Body Width

    2.070 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    4.390 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.760 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.020 inches minimum and

  • Iii Fragility Factor

    moderately rugged

  • Pole Quantity

    2

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Iii Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • External Actuator Linkage Arrangement

    one and two linked

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.350 minimum at 200 pct and

  • Inclosure Protection Type For Which Designed

    fungus proof

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 compression and

  • Terminal Type And Quantity

    2 tab, solder lug

  • Body Length

    4.760 inches maximum

  • Body Width

    2.050 inches minimum and

  • Body Height

    2.600 inches minimum and

  • Body Height

    2.620 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    4.370 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Width

    1.020 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Width

    1.040 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.138 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.040 inches maximum

  • Mounting Facility Type And Quantity

    4 threaded hole and

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    2 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    dustproof and

  • Frequency In Hertz

    60.0 all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...