NSN: 5925-00-430-9706

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    multipole-multiple actuator type

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Body Width

    1.468 inches minimum and 1.532 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.555 inches minimum and 1.565 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.745 inches minimum and 0.755 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.835 inches minimum and 1.845 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    2 toggle

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one and two linked

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 20.000 maximum at 200 pct

  • Thread Series Designator

    unc

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.745 inches minimum and 0.755 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.655 inches minimum and 1.665 inches maximum

  • Boss Height

    0.125 inches minimum and 0.135 inches maximum

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Circuit Protection Type

    overcurrent

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    dustproof and fungus resistant

  • Frequency In Hertz

    60.0

  • Terminal Type And Quantity

    4 tab,solder lug

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...