NSN: 5925-00-433-1821

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    4 screw

  • Body Style

    11b multipole-single actuator type

  • Body Width

    2.750 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    5.812 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.188 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac and

  • Trip Release Method

    thermal-magnetic all locations

  • Trip Release Characteristic

    time delay all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Trip Delay Time In Seconds Per Rated Continuous Current

    25.000 minimum at 200 pct and

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Body Length

    6.312 inches nominal

  • Body Height

    3.188 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.875 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Boss Height

    0.156 inches nominal

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac and

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac and

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    instantaneous and

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    90.000 maximum at 200 pct all locations

  • Frequency In Hertz

    60.0 all locations

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Special Features

    shunt trip pole one 120 vac

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...