NSN: 5925-00-434-3703
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
2 threaded stud
-
Thread Series Designator
unc
-
Unpackaged Unit Weight
3.700 ounces
-
Frequency In Hertz
50.0 or b60.0
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 22.000 maximum at 200 pct
-
Nominal Thread Size
0.138 inches
-
Internal Trip Release Configuration
series trip
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0
-
Trip Release Method
magnetic
-
Thread Quantity Per Inch
32
-
Storage Type
general purpose warehouse
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant and salt spray proof and vibration resistant and shock resistant
-
Mounting Facility Type And Quantity
2 threaded hole
-
Arc Quenching Method
magnetic blowout
-
Pole Quantity
1
-
Mounting Surface To Terminal End Distance
2.475 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Case Material
plastic
-
Body Length
2.480 inches minimum and 2.500 inches maximum
-
Thread Pitch Diameters
p0.1177/p0.1214 inches
-
Actuator Position Designation
at pole one
-
Actuator Function
trip-reset
-
Manual Actuator Type And Quantity
1 toggle
-
Reset Method
manual
-
Trip Release Characteristic
time delay
-
Circuit Protection Type
overcurrent
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac
-
Special Handling Feature
magnetic
-
Boss Height
0.150 inches nominal
-
Fragility Factor
moderately rugged
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Body Width
0.750 inches maximum