NSN: 5925-00-434-4175

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    60.0 single location

  • Inclosure Protection Type For Which Designed

    moisture resistant and salt spray proof and vibrationproof and ice resistant

  • Ultimate Trip Time Per Pole In Seconds

    6.003 minimum single location and 0.040 maximum single location

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    277.0 ac single location

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    1000.0 single location

  • Terminal Type And Quantity

    2 tab, solder lug

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    12.000 maximum at 125 pct single location and 4.000 maximum at 150 pct single location and 0.130 maximum at 600 pct single location and 0.008 minimum at 600 pct single location and 0.220 maximum at 400 pct single location and 0.003 minimum at 800 pct

  • ~1

    single location and 1.300 maximum at 200 pct sing

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Thread Series Designator

    unc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Special Features

    handle color with on-off markings black with white markings

  • Actuator Position Designation

    at pole one

  • Body Width

    0.750 inches nominal

  • Body Length

    2.000 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...