NSN: 5925-00-434-9054

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Terminal Type

    tab, solder lug

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    4.750 inches nominal

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Switch Current Rating And Type In Amps

    10.0 ac and 10.0 dc

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Switch Contact Arrangement

    single pole, double throw

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    3.625 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac all locations and 125.0 dc all locations

  • Inclosure Protection Type For Which Designed

    general purpose

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations and 5000.0 dc all locations

  • Frequency In Hertz

    400.0 all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Boss Height

    0.312 inches nominal

  • Mounting Surface To Terminal End Distance

    4.625 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Body Length

    5.000 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    200.0 amperes ac all locations and 200.0 amperes dc all locations

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 125.0 dc

  • Terminal Type And Quantity

    6 threaded stud

  • Trip Delay Time In Seconds Per Rated Continuous Current

    75.000 minimum at 200 pct all locations and 160.000 maximum at 200 pct all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.250 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...