NSN: 5925-00-435-3783

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Protection Type For Which Designed

    fungus resistant and shock resistant

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    30.0 dc single location

  • Overall Length

    2.000 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    600.0 dc single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches nominal

  • Unpackaged Unit Weight

    1.750 ounces

  • Body Style

    single pole type

  • Nominal Thread Size

    0.164 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.574 inches nominal

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    1.266 inches nominal

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Terminal Type And Quantity

    2 screw

  • Manual Actuator Type And Quantity

    1 push button

  • Body Width

    1.250 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 10.000 maximum at 200 pct single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    130.0 single location

  • Fragility Factor

    moderately rugged

  • Actuator Function

    reset

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...