NSN: 5925-00-435-3849

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Method

    thermal all locations

  • Actuator Function

    reset

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct all locations and 65.000 maximum at 200 pct all locations

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    80.0 amperes ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.875 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.875 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.437 inches nominal

  • Arc Quenching Method

    air

  • Body Style

    multipole-multiple actuator type

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Case Material

    metal

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    60.0 all locations

  • Mounting Surface To Terminal End Distance

    2.046 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    6 screw

  • Body Width

    2.187 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Body Length

    2.593 inches nominal

  • Manual Actuator Type And Quantity

    3 push button

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    160.0 ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.