NSN: 5925-00-435-8390

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    60.0 single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.035 inches minimum and 2.085 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.015 minimum at 200 pct single location and 0.040 maximum at 200 pct single location

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Body Length

    2.465 inches minimum and 2.515 inches maximum

  • Special Handling Feature

    magnetic

  • Boss Height

    0.110 inches minimum and 0.170 inches maximum

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Body Width

    0.723 inches minimum and 0.765 inches maximum

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location

  • Unpackaged Unit Weight

    0.250 pounds

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Surface To Terminal End Distance

    2.578 inches minimum and 2.640 inches maximum

  • Inclosure Protection Type For Which Designed

    general purpose

  • Center To Center Distance Between Terminals Parallel To Length

    1.909 inches minimum and 1.967 inches maximum

  • Body Style

    single pole type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...