Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Features Provided

    adjustable trip release

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations and 250.0 dc all locations

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Unthreaded Mounting Hole Diameter

    0.312 inches nominal

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +1880.0/+2280.0 ac all locations and +1880.0/+2280.0 dc all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    3.000 inches nominal

  • Overall Height

    9.687 inches nominal

  • Body Length

    17.938 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    3.000 inches nominal

  • Frequency In Hertz

    60.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Boss Height

    0.250 inches nominal

  • Body Style

    multipole-single actuator type

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Actuator Position Designation

    at pole two

  • Body Width

    9.000 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Center To Center Distance Between Terminals Parallel To Length

    15.125 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    300.0 amperes ac all locations and 300.0 amperes dc all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    17.000 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    30000.0 ac all locations and 20000.0 dc all locations

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...