NSN: 5925-00-443-9446

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    4 compression

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Mounting Facility Type And Quantity

    2 unthreaded hole and 2 slot

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 250.0 dc

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Trip Release Characteristic

    instantaneous all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Trip Release Ambient Temp Rating

    40.0 deg celsius maximum all locations

  • Mounting Slot Width

    0.750 inches nominal

  • Body Style

    11b multipole-single actuator type

  • Body Length

    6.000 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.164 inches nominal

  • Body Width

    3.000 inches nominal

  • Body Height

    3.344 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    5.125 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.594 inches nominal

  • Boss Height

    0.219 inches nominal

  • Pole Quantity

    2

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac all locations and 40.0 amperes dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac all locations and 10000.0 dc

  • Inclosure Protection Type For Which Designed

    fungus resistant

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...