Technical Characteristics

  • Body Width

    0.615 inches minimum and 0.635 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct single location and 2.000 maximum at 200 pct single location

  • Pole Quantity

    1

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Length

    0.529 inches minimum and 0.591 inches maximum

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Special Handling Feature

    magnetic

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Auxiliary Switch Function And Quantity

    1 control

  • Switch Location And Position Designation

    internal at pole one

  • Nominal Thread Size

    0.469 inches

  • Bushing Length

    0.280 inches minimum and 0.300 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc single location

  • Mounting Surface To Terminal End Distance

    1.623 inches minimum and 1.653 inches maximum

  • Terminal Type And Quantity

    2 tab w/screw

  • Switch Terminal Type

    pin

  • Switch Contact Arrangement

    single pole, single throw, normally open

  • Body Style

    single pole type

  • Switch Current Rating And Type In Amps

    7.0 dc

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes dc single location

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Body Length

    1.735 inches minimum and 1.765 inches maximum

  • Inclosure Protection Type For Which Designed

    vibration resistant

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...