NSN: 5925-00-451-8682

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Switch Terminal Type

    tab, solder lug

  • Bushing Length

    0.250 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    12.0 amperes dc single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Center To Center Distance Between Terminals Parallel To Length

    1.341 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    2 screw

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Body Width

    0.656 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    shockproof and vibrationproof

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Switch Current Rating And Type In Amps

    7.0 dc

  • Body Style

    single pole type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 4.000 maximum at 200 pct single location

  • Unpackaged Unit Weight

    0.125 pounds

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc single location

  • Mounting Surface To Terminal End Distance

    1.669 inches nominal

  • Nominal Thread Size

    0.469 inches

  • Body Length

    1.781 inches nominal

  • Switch Location And Position Designation

    internal at pole one

  • Thread Series Designator

    uns

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...