NSN: 5925-00-464-4668
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Body Style
single pole type
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
-
Switch Terminal Type
solder stud
-
Auxiliary Switch Function And Quantity
1 control
-
Case Material
plastic
-
Terminal Type And Quantity
2 threaded stud
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Actuator Function
trip-reset
-
Storage Type
general purpose warehouse
-
Actuator Position Designation
at pole one
-
Trip Release Ambient Temp Rating
45.0 deg celsius nominal single location
-
Mounting Surface To Terminal End Distance
2.900 inches nominal
-
Reset Method
manual
-
Thread Series Designator
unc
-
Test Data Document
18876-11077014 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Maximum Continuous Load Current Rating Per Pole
12.0 amperes dc single location
-
Special Handling Feature
magnetic
-
Fragility Factor
moderately rugged
-
Boss Height
0.140 inches nominal
-
Arc Quenching Method
magnetic blowout
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Trip Release Characteristic
time delay single location
-
Trip Release Method
thermal-magnetic single location
-
Switch Location And Position Designation
external at pole one
-
Nominal Thread Size
0.138 inches
-
Manual Actuator Type And Quantity
1 toggle
-
Pole Quantity
1
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc
-
Switch Contact Arrangement
single pole, double throw
-
Body Width
0.760 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct single location and 0.500 maximum at 200 pct single location
-
Circuit Protection Type
overcurrent single location
-
Thread Quantity Per Inch
32
-
Body Length
2.530 inches nominal
-
Mounting Facility Type And Quantity
2 threaded hole
-
Ultimate Trip Time Per Pole In Seconds
0.700 minimum single location and 2.800 maximum single location