NSN: 5925-00-467-1356

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Contact Arrangement

    single pole,double throw

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.109 inches minimum and 0.171 inches maximum

  • Mounting Surface To Terminal End Distance

    2.800 inches maximum

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Thread Quantity Per Inch

    32

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    internal at pole two

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.200 minimum at 200 pct and 20.000 maximum at 200 pct

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Frequency In Hertz

    60.0

  • Test Data Document

    81349-mil-c-55629 specification

  • Specification/Standard Data

    81349-mil-c-55629/6 government specification

  • Body Length

    2.510 inches maximum

  • Body Width

    2.156 inches minimum and 2.344 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.719 inches minimum and 0.781 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and 2.078 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    4.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Terminal Type

    tab,solder lug

  • Switch Current Rating And Type In Amps

    10.0 ac and 2.0 dc

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...