NSN: 5925-00-472-0575
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Nominal Thread Size
0.190 inches
-
Thread Series Designator
unf
-
Actuator Position Designation
at pole one
-
Precious Material
silver
-
Body Width
0.750 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
4.0 amperes ac single location
-
Trip Release Ambient Temp Rating
40.0 deg fahrenheit minimum single location and 115.0 deg fahrenheit maximum single location
-
Mounting Surface To Terminal End Distance
2.611 inches nominal
-
End Item Identification
an/alq-119
-
Precious Material And Location
stud and nut external surfaces silver
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location
-
Boss Height
1.125 inches nominal
-
Pole Quantity
1
-
Inclosure Protection Type For Which Designed
shock resistant and humidity resistant and vibration resistant
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Mounting Facility Type And Quantity
2 threaded stud
-
Body Length
2.500 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location
-
Body Style
single pole type
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 nominal at 125 pct single location and 1.500 nominal at 100 pct single location and 0.120 nominal at 300 pct single location
-
Trip Release Method
magnetic-hydraulic single location
-
Frequency In Hertz
60.0 single location
-
Reset Method
automatic
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
-
Terminal Type And Quantity
2 threaded stud