NSN: 5925-00-481-8873
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
2 threaded stud
-
Case Material
plastic
-
Switch Contact Arrangement
single pole,double throw
-
Mounting Surface To Terminal End Distance
2.809 inches maximum
-
Pole Quantity
1
-
Mounting Facility Type And Quantity
2 threaded stud
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes dc
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc
-
Trip Release Method
magnetic
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
reset
-
Internal Trip Release Configuration
series trip
-
Nominal Thread Size
0.138 inches
-
Switch Location And Position Designation
internal at each pole
-
Thread Series Designator
unc
-
Body Length
2.515 inches maximum
-
Auxiliary Switch Function And Quantity
1 control
-
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct and 70.000 maximum at 200 pct
-
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Body Width
0.710 inches minimum and 0.760 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.939 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.061 inches nominal
-
Boss Height
0.100 inches minimum and 0.165 inches maximum
-
Circuit Protection Type
overcurrent
-
Trip Release Characteristic
time delay
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Position Designation
at each pole